<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ePoE Switches &#8211; Dahua Indonesia</title>
	<atom:link href="https://www.cctvdahua.co.id/product-category/transmission/epoe-switches/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cctvdahua.co.id</link>
	<description>camera cctv dahua. Smart Security. Dahua Technology</description>
	<lastBuildDate>Mon, 15 Oct 2018 19:53:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.cctvdahua.co.id/wp-content/uploads/2026/03/cropped-dahua-bandung-32x32.png</url>
	<title>ePoE Switches &#8211; Dahua Indonesia</title>
	<link>https://www.cctvdahua.co.id</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PFL2106-4ET-96</title>
		<link>https://www.cctvdahua.co.id/product/pfl2106-4et-96/</link>
		
		<dc:creator><![CDATA[kim]]></dc:creator>
		<pubDate>Mon, 15 Oct 2018 19:53:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.cctvdahua.co.id/?post_type=product&#038;p=10267</guid>

					<description><![CDATA[<p class="text" data-v-5c66813e="">4-Port ePoE Switch</p>

<div data-v-5c66813e="">&#62; Supports long distance PoE transmission up to 800m with ePoE technology of Dahua
&#62; Two-layer industrial PoE switch
&#62; MAC auto study and aging, MAC address list capacity is 8K
&#62; Conform IEEE802.3, IEEE802.3u, IEEE802.3ab/z and IEEE802.3X standards
&#62; Supports IEEE802.3af, IEEE802.3at, Hi-PoE standard
&#62; Industrial wide temperature design</div>

[otw_shortcode_button href="https://www.cctvdahua.co.id/wp-content/uploads/2018/10/DH-PFL2106-4ET-96_Datasheet_20180426.pdf" size="large" icon_position="right" shape="round" target="_blank"]Download[/otw_shortcode_button]
]]></description>
										<content:encoded><![CDATA[<div id="div_left">
<div class="div-drop">
<table id="table001" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Technical Speciﬁcation</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-PFL2106-4ET-96</td>
</tr>
<tr>
<td colspan="18">Ethernet Port</td>
<td colspan="42">1*100/1000 Base-X</p>
<p>1*10/100/1000 Base-T</p>
<p>4*10/100 Base-T(PoE power supply)</td>
</tr>
<tr>
<td colspan="18">PoE Power Consumption</td>
<td colspan="42">Port1,2,3≤30W, Port4≤60W, Total≤96W</td>
</tr>
<tr>
<td colspan="18">PoE Protocol</td>
<td colspan="42">IEEE802.3af, IEEE802.3at, Hi-PoE</td>
</tr>
<tr>
<td colspan="18">Switching Capacity</td>
<td colspan="42">6.8Gbps</td>
</tr>
<tr>
<td colspan="18">Packet Forwarding Rate</td>
<td colspan="42">3.57Mpps</td>
</tr>
<tr>
<td colspan="18">Packet Buffer Memory</td>
<td colspan="42">1Mb</td>
</tr>
<tr>
<td colspan="18">MAC Table Size</td>
<td colspan="42">8K</td>
</tr>
<tr>
<td colspan="18">Flow Control</td>
<td colspan="42">Enable by default</td>
</tr>
<tr>
<td colspan="18">Application Humidity</td>
<td colspan="42">10%~90%</td>
</tr>
<tr>
<td colspan="18">Power</td>
<td colspan="42">DC48~57V power adapter</td>
</tr>
<tr>
<td colspan="18">Lightning Protection</td>
<td colspan="42">Common Mode 4KV</p>
<p>Differential Mode 2KV</td>
</tr>
<tr>
<td colspan="18">Working Temperature</td>
<td colspan="42">﹣30°C~65°C</td>
</tr>
<tr>
<td colspan="18">Weight</td>
<td colspan="42">480g</td>
</tr>
<tr>
<td colspan="18">Dimension(W×D×H)</td>
<td colspan="42">150mm×100mm×30mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table002" class="基本表 tab-drag table-border">
<tbody>
<tr>
<td colspan="60">Transmission Performance:</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">33</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">19</td>
<td colspan="10">19</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">17</td>
<td colspan="10">17</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">7</td>
<td colspan="10">7</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch supply voltage 48V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">47</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">32</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">23</td>
<td colspan="10">26</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">20</td>
<td colspan="10">20</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch supply voltage 53V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table003" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Accessories</td>
</tr>
<tr>
<td colspan="18">SFP Module</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">PFT3900</td>
<td colspan="42">155M 850nm,2km,LC, Multi-mode</td>
</tr>
<tr>
<td colspan="18">PFT3950</td>
<td colspan="42">1.25G 850nm,500m,LC, Multi-mode</td>
</tr>
<tr>
<td colspan="18">PFT3910</td>
<td colspan="42">155M 1310/1550nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3920</td>
<td colspan="42">155M 1550/1310nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3960</td>
<td colspan="42">1.25G 1310/1550nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3970</td>
<td colspan="42">1.25G 1550/1310nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18"></td>
<td colspan="42"></td>
</tr>
<tr>
<td colspan="18">EoC (Ethernet over Coax)</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">LR1002</td>
<td colspan="42">1*10/100 Mbps Base-TX + 1*BNC</p>
<p>RG59 coaxial cable:</p>
<p>400m/100Mbps, 1000m/10Mbps</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LR2226-24ET-360</title>
		<link>https://www.cctvdahua.co.id/product/lr2226-24et-360/</link>
		
		<dc:creator><![CDATA[kim]]></dc:creator>
		<pubDate>Mon, 15 Oct 2018 19:52:45 +0000</pubDate>
				<guid isPermaLink="false">https://www.cctvdahua.co.id/?post_type=product&#038;p=10264</guid>

					<description><![CDATA[<p class="text" data-v-5c66813e="">24-Port ePoE Switch</p>

<div data-v-5c66813e="">&#62; Supports long distance PoE transmission up to 800m with ePoE technology of Dahua
&#62; Layer-two web managed ePoE switch
&#62; Port 1-8 support three self-adaptive transmission modes which are IEEE, E100 and E10
&#62; Port 1-8 support both twisted-pair transmission and coaxial cable transmission
&#62; Support web management: port management, 802.1Q VLAN, STP/RSTP, LACP, 802.1X, QoS
&#62; Support PoE management, Green PoE, Legacy Support
&#62; Conform IEEE802.3, IEEE802.3u, IEEE802.3ab/z and IEEE802.3X standards</div>

[otw_shortcode_button href="https://www.cctvdahua.co.id/wp-content/uploads/2018/10/DH-LR2226-24ET-360_Datasheet_20180608.pdf" size="large" icon_position="right" shape="round" target="_blank"]Download[/otw_shortcode_button]
]]></description>
										<content:encoded><![CDATA[<div id="div_left">
<div class="div-drop">
<table id="table001" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Technical Speciﬁcation</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-LR2226-24ET-360</td>
</tr>
<tr>
<td colspan="18">Ethernet Port</td>
<td colspan="42">2*10/100/1000 Base-T</p>
<p>2*1000 Base-X (Combo ports)</p>
<p>24*10/100 Base-T (PoE power supply)</td>
</tr>
<tr>
<td colspan="18">PoE Power Consumption</td>
<td colspan="42">Port1 and port 2 support Hi-PoE 60W</p>
<p>Each power≤30W, Total≤360W</td>
</tr>
<tr>
<td colspan="18">PoE Protocol</td>
<td colspan="42">IEEE802.3af, IEEE802.3at, Hi-PoE</td>
</tr>
<tr>
<td colspan="18">Switching Capacity</td>
<td colspan="42">8.8Gbps</td>
</tr>
<tr>
<td colspan="18">Packet Forwarding Rate</td>
<td colspan="42">6.55Mpps</td>
</tr>
<tr>
<td colspan="18">Packet Buffer Memory</td>
<td colspan="42">2.75Mb</td>
</tr>
<tr>
<td colspan="18">Application Humidity</td>
<td colspan="42">10%~90%</td>
</tr>
<tr>
<td colspan="18">Power</td>
<td colspan="42">AC100-240V, 50/60Hz</td>
</tr>
<tr>
<td colspan="18">Lightning Protection</td>
<td colspan="42">Common Mode 4KV</p>
<p>Differential Mode 2KV</td>
</tr>
<tr>
<td colspan="18">Working Temperature</td>
<td colspan="42">﹣10°C~55°C</td>
</tr>
<tr>
<td colspan="18">Weight</td>
<td colspan="42">3.12kg</td>
</tr>
<tr>
<td colspan="18">Dimension(W×D×H)</td>
<td colspan="42">440mm x300mm x44mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table002" class="基本表 tab-drag">
<tbody>
<tr>
<td colspan="60">Transmission Performance:</td>
</tr>
<tr>
<td colspan="60">ePoE Power Supply Specifications (CAT)</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">47</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">32</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">23</td>
<td colspan="10">26</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">20</td>
<td colspan="10">20</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 51V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
<tr>
<td colspan="60">ePoE Power Supply Specifications (RG59 Coaxial Cable)</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">52</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">48</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">30</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">100</td>
<td colspan="10">20</td>
<td colspan="10">23</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">16</td>
<td colspan="10">16</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">10</td>
<td colspan="10">10</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">1000</td>
<td colspan="10">10</td>
<td colspan="10">8</td>
<td colspan="10">8</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 51V.</p>
<p>RG-59, max. DC resistance &lt; 5Ω/100m.</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table003" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Service Characteristics</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-LR2226-24ET-360</td>
</tr>
<tr>
<td colspan="18" rowspan="2">System</td>
<td colspan="42">Username / password: admin/User Define</td>
</tr>
<tr>
<td colspan="42">IP Address :192.168.1.110/24</td>
</tr>
<tr>
<td colspan="18">PoE Budget</td>
<td colspan="42">360W</td>
</tr>
<tr>
<td colspan="18">MAC Table</td>
<td colspan="42">4K</td>
</tr>
<tr>
<td colspan="18">VLAN</td>
<td colspan="42">802.1Q Standard VLAN</td>
</tr>
<tr>
<td colspan="18">Spanning Tree</td>
<td colspan="42">STP, RSTP</td>
</tr>
<tr>
<td colspan="18">Port Aggregation</td>
<td colspan="42">Static link aggregation, LACP</td>
</tr>
<tr>
<td colspan="18">Mirroring</td>
<td colspan="42">Support many-to-one port mirroring</td>
</tr>
<tr>
<td colspan="18">DHCP</td>
<td colspan="42">Support DHCP-Client</td>
</tr>
<tr>
<td colspan="18">Long Distance Mode</td>
<td colspan="42">Extend the maximum distance from 100m to 800m</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Flow Control</td>
<td colspan="42">Support half-duplex based on back pressure type control;</td>
</tr>
<tr>
<td colspan="42">Support full duplex based on PAUSE frame</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Security Features</td>
<td colspan="42">Hardware supports IP+MAC binding based on port</td>
</tr>
<tr>
<td colspan="42">Support IEEE802.1x port authentication</td>
</tr>
<tr>
<td colspan="18" rowspan="3">System Maintenance</td>
<td colspan="42">one-key recovery of default</td>
</tr>
<tr>
<td colspan="42">Support the updated packet upload</td>
</tr>
<tr>
<td colspan="42">Support system logs</td>
</tr>
<tr>
<td colspan="18" rowspan="3">QoS</td>
<td colspan="42">Support high and low priority, WRR</td>
</tr>
<tr>
<td colspan="42">Support 802.1P, DSCP</td>
</tr>
<tr>
<td colspan="42">Support priority according to protocol</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Network Management</td>
<td colspan="42">WEB(http and https protocol)</td>
</tr>
<tr>
<td colspan="42">Support SNMP V1/V2C/V3</td>
</tr>
<tr>
<td colspan="18" rowspan="4">PoE Management</td>
<td colspan="42">Support PoE power consumption, PoE on/off of IPC configura-tion, power down when exceeding the value of overload power</td>
</tr>
<tr>
<td colspan="42">Support PoE event statics</td>
</tr>
<tr>
<td colspan="42">Support Green PoE</td>
</tr>
<tr>
<td colspan="42">Support Legacy Support</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table004" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Accessories</td>
</tr>
<tr>
<td colspan="18">SFP Module</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">PFT3950</td>
<td colspan="42">1.25G 850nm,500m,LC, Multi-mode</td>
</tr>
<tr>
<td colspan="18">PFT3960</td>
<td colspan="42">1.25G 1310/1550nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3970</td>
<td colspan="42">1.25G 1550/1310nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18"></td>
<td colspan="42"></td>
</tr>
<tr>
<td colspan="18">EoC (Ethernet over Coax)</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">LR1002</td>
<td colspan="42">1*10/100 Mbps Base-TX + 1*BNC</p>
<p>RG59 coaxial cable:</p>
<p>400m/100Mbps, 1000m/10Mbps</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LR2218-16ET-240</title>
		<link>https://www.cctvdahua.co.id/product/lr2218-16et-240/</link>
		
		<dc:creator><![CDATA[kim]]></dc:creator>
		<pubDate>Mon, 15 Oct 2018 19:51:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.cctvdahua.co.id/?post_type=product&#038;p=10261</guid>

					<description><![CDATA[<p class="text" data-v-5c66813e="">16-Port ePoE Switch</p>

<div data-v-5c66813e="">&#62; Supports long distance PoE transmission up to 800m with ePoE technology of Dahua
&#62; Layer-two web managed ePoE switch
&#62; Port 1-8 support three self-adaptive transmission modes which are IEEE, E100 and E10
&#62; Port 1-8 support both twisted-pair transmission and coaxial cable transmission
&#62; Support web management: port management, 802.1Q VLAN, STP/RSTP, LACP, 802.1X, QoS
&#62; Support PoE management, Green PoE, Legacy Support
&#62; Conform IEEE802.3, IEEE802.3u, IEEE802.3ab/z and IEEE802.3X standards</div>

[otw_shortcode_button href="https://www.cctvdahua.co.id/wp-content/uploads/2018/10/DH-LR2218-16ET-240_Datasheet_20180608.pdf" size="large" icon_position="right" shape="round" target="_blank"]Download[/otw_shortcode_button]
]]></description>
										<content:encoded><![CDATA[<div id="div_left">
<div class="div-drop">
<table id="table001" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Technical Speciﬁcation</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-LR2218-16ET-240</td>
</tr>
<tr>
<td colspan="18">Ethernet Port</td>
<td colspan="42">2*10/100/1000 Base-T</p>
<p>2*1000 Base-X (Combo ports)</p>
<p>16*10/100 Base-T (PoE power supply)</td>
</tr>
<tr>
<td colspan="18">PoE Power Consumption</td>
<td colspan="42">Port1 and port 2 support Hi-PoE 60W</p>
<p>Each power≤30W, Total≤240W</td>
</tr>
<tr>
<td colspan="18">PoE Protocol</td>
<td colspan="42">IEEE802.3af, IEEE802.3at, Hi-PoE</td>
</tr>
<tr>
<td colspan="18">Switching Capacity</td>
<td colspan="42">8.8Gbps</td>
</tr>
<tr>
<td colspan="18">Packet Forwarding Rate</td>
<td colspan="42">5.36Mpps</td>
</tr>
<tr>
<td colspan="18">Packet Buffer Memory</td>
<td colspan="42">2.75Mb</td>
</tr>
<tr>
<td colspan="18">Application Humidity</td>
<td colspan="42">10%~90%</td>
</tr>
<tr>
<td colspan="18">Power</td>
<td colspan="42">AC100-240V, 50/60Hz</td>
</tr>
<tr>
<td colspan="18">Lightning Protection</td>
<td colspan="42">Common Mode 4KV</p>
<p>Differential Mode 2KV</td>
</tr>
<tr>
<td colspan="18">Working Temperature</td>
<td colspan="42">﹣10°C~55°C</td>
</tr>
<tr>
<td colspan="18">Weight</td>
<td colspan="42">3.12kg</td>
</tr>
<tr>
<td colspan="18">Dimension(W×D×H)</td>
<td colspan="42">440mm x300mm x44mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table002" class="基本表 tab-drag table-border">
<tbody>
<tr>
<td colspan="60">Transmission Performance:</td>
</tr>
<tr>
<td colspan="60">ePoE Power Supply Specifications (CAT)</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">47</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">32</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">23</td>
<td colspan="10">26</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">20</td>
<td colspan="10">20</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 51V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
<tr>
<td colspan="60">ePoE Power Supply Specifications (RG59 Coaxial Cable)</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">52</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">48</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">30</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">100</td>
<td colspan="10">20</td>
<td colspan="10">23</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">16</td>
<td colspan="10">16</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">10</td>
<td colspan="10">10</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">1000</td>
<td colspan="10">10</td>
<td colspan="10">8</td>
<td colspan="10">8</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 51V.</p>
<p>RG-59, max. DC resistance &lt; 5Ω/100m.</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table003" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Service Characteristics</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-LR2218-16ET-240</td>
</tr>
<tr>
<td colspan="18" rowspan="2">System</td>
<td colspan="42">Username / password: admin/User Define</td>
</tr>
<tr>
<td colspan="42">IP Address :192.168.1.110/24</td>
</tr>
<tr>
<td colspan="18">PoE Budget</td>
<td colspan="42">240W</td>
</tr>
<tr>
<td colspan="18">MAC Table</td>
<td colspan="42">4K</td>
</tr>
<tr>
<td colspan="18">VLAN</td>
<td colspan="42">802.1Q Standard VLAN</td>
</tr>
<tr>
<td colspan="18">Spanning Tree</td>
<td colspan="42">STP, RSTP</td>
</tr>
<tr>
<td colspan="18">Port Aggregation</td>
<td colspan="42">Static link aggregation, LACP</td>
</tr>
<tr>
<td colspan="18">Mirroring</td>
<td colspan="42">Support many-to-one port mirroring</td>
</tr>
<tr>
<td colspan="18">DHCP</td>
<td colspan="42">Support DHCP-Client</td>
</tr>
<tr>
<td colspan="18">Long Distance Mode</td>
<td colspan="42">Extend the maximum distance from 100m to 800m</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Flow Control</td>
<td colspan="42">Support half-duplex based on back pressure type control;</td>
</tr>
<tr>
<td colspan="42">Support full duplex based on PAUSE frame</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Security Features</td>
<td colspan="42">Hardware supports IP+MAC binding based on port</td>
</tr>
<tr>
<td colspan="42">Support IEEE802.1x port authentication</td>
</tr>
<tr>
<td colspan="18" rowspan="3">System Maintenance</td>
<td colspan="42">one-key recovery of default</td>
</tr>
<tr>
<td colspan="42">Support the updated packet upload</td>
</tr>
<tr>
<td colspan="42">Support system logs</td>
</tr>
<tr>
<td colspan="18" rowspan="3">QoS</td>
<td colspan="42">Support high and low priority, WRR</td>
</tr>
<tr>
<td colspan="42">Support 802.1P, DSCP</td>
</tr>
<tr>
<td colspan="42">Support priority according to protocol</td>
</tr>
<tr>
<td colspan="18" rowspan="2">Network Management</td>
<td colspan="42">WEB(http and https protocol)</td>
</tr>
<tr>
<td colspan="42">Support SNMP V1/V2C/V3</td>
</tr>
<tr>
<td colspan="18" rowspan="4">PoE Management</td>
<td colspan="42">Support PoE power consumption, PoE on/off of IPC configura-tion, power down when exceeding the value of overload power</td>
</tr>
<tr>
<td colspan="42">Support PoE event statics</td>
</tr>
<tr>
<td colspan="42">Support Green PoE</td>
</tr>
<tr>
<td colspan="42">Support Legacy Support</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table004" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Accessories</td>
</tr>
<tr>
<td colspan="18">SFP Module</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">PFT3950</td>
<td colspan="42">1.25G 850nm,500m,LC, Multi-mode</td>
</tr>
<tr>
<td colspan="18">PFT3960</td>
<td colspan="42">1.25G 1310/1550nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3970</td>
<td colspan="42">1.25G 1550/1310nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18"></td>
<td colspan="42"></td>
</tr>
<tr>
<td colspan="18">EoC (Ethernet over Coax)</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">LR1002</td>
<td colspan="42">1*10/100 Mbps Base-TX + 1*BNC</p>
<p>RG59 coaxial cable:</p>
<p>400m/100Mbps, 1000m/10Mbps</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LR2110-8ET-120</title>
		<link>https://www.cctvdahua.co.id/product/lr2110-8et-120/</link>
		
		<dc:creator><![CDATA[kim]]></dc:creator>
		<pubDate>Mon, 15 Oct 2018 19:51:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.cctvdahua.co.id/?post_type=product&#038;p=10258</guid>

					<description><![CDATA[<p class="text" data-v-5c66813e="">8-Port ePoE Switch</p>

<div data-v-5c66813e="">&#62; Supports long distance PoE transmission up to 800m with ePoE technology of Dahua
&#62; Layer-two ePoE switch
&#62; MAC auto study and aging, MAC address list capacity is 8K
&#62; Conform IEEE802.3, IEEE802.3u, IEEE802.3ab/z and IEEE802.3X standards
&#62; Supports IEEE802.3af, IEEE802.3at, Hi-PoE standard
&#62; Industrial wide temperature design
&#62; Port indicator light is to display the status of current transmission mode for the port, which includes IEEE, E100 and E10</div>

[otw_shortcode_button href="https://www.cctvdahua.co.id/wp-content/uploads/2018/10/DH-LR2110-8ET-120_datasheet.pdf" size="large" icon_position="right" shape="round" target="_blank"]Download[/otw_shortcode_button]
]]></description>
										<content:encoded><![CDATA[<div id="div_left">
<div class="div-drop">
<table id="table001" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Technical Speciﬁcation</td>
</tr>
<tr>
<td colspan="18">Model</td>
<td colspan="42">DH-LR2110-8ET-120</td>
</tr>
<tr>
<td colspan="18">Ethernet Port</td>
<td colspan="42">1*1000 Base-X</p>
<p>1*10/100/1000 Base-T</p>
<p>8*10/100 Base-T(PoE power supply)</td>
</tr>
<tr>
<td colspan="18">PoE Power Consumption</td>
<td colspan="42">Port1,5≤60W, Port2,3,4,6,7,8≤30W, Total≤120W</td>
</tr>
<tr>
<td colspan="18">PoE Protocol</td>
<td colspan="42">IEEE802.3af, IEEE802.3at, Hi-PoE</td>
</tr>
<tr>
<td colspan="18">Switching Capacity</td>
<td colspan="42">8.8Gbps</td>
</tr>
<tr>
<td colspan="18">Packet Forwarding Rate</td>
<td colspan="42">4.17Mpps</td>
</tr>
<tr>
<td colspan="18">Packet Buffer Memory</td>
<td colspan="42">2.75Mb</td>
</tr>
<tr>
<td colspan="18">MAC Table Size</td>
<td colspan="42">8K</td>
</tr>
<tr>
<td colspan="18">Flow Control</td>
<td colspan="42">Enable by default</td>
</tr>
<tr>
<td colspan="18">Application Humidity</td>
<td colspan="42">10%~90%</td>
</tr>
<tr>
<td colspan="18">Power</td>
<td colspan="42">DC48~57V power adapter</td>
</tr>
<tr>
<td colspan="18">Lightning Protection</td>
<td colspan="42">Common Mode 4KV</p>
<p>Differential Mode 2KV</td>
</tr>
<tr>
<td colspan="18">Working Temperature</td>
<td colspan="42">﹣30°C~65°C</td>
</tr>
<tr>
<td colspan="18">Weight</td>
<td colspan="42">0.59kg</td>
</tr>
<tr>
<td colspan="18">Dimension(W×D×H)</td>
<td colspan="42">150mm×100mm×42mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table002" class="基本表 tab-drag">
<tbody>
<tr>
<td colspan="60">Transmission Performance:</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">33</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">19</td>
<td colspan="10">19</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">17</td>
<td colspan="10">17</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">7</td>
<td colspan="10">7</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 48V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
<tr>
<td colspan="18">Cable (m)</td>
<td colspan="10">Bandwidth (Mbps)</td>
<td colspan="10">PoE Load Capacity (W)</td>
<td colspan="10">Hi-PoE Load Capacity (W)</td>
<td colspan="12">Working Mode</td>
</tr>
<tr>
<td colspan="18">100</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">53</td>
<td colspan="12">IEEE/E100</td>
</tr>
<tr>
<td colspan="18">200</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">47</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">300</td>
<td colspan="10">100</td>
<td colspan="10">25.5</td>
<td colspan="10">32</td>
<td colspan="12">E100</td>
</tr>
<tr>
<td colspan="18">400</td>
<td colspan="10">10</td>
<td colspan="10">23</td>
<td colspan="10">26</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">500</td>
<td colspan="10">10</td>
<td colspan="10">20</td>
<td colspan="10">20</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="18">800</td>
<td colspan="10">10</td>
<td colspan="10">13</td>
<td colspan="10">13</td>
<td colspan="12">E10</td>
</tr>
<tr>
<td colspan="60">ePoE switch power supply voltage 53V</p>
<p>CAT5E/CAT6, max. DC resistance &lt; 10Ω/100m</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table003" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">Accessories</td>
</tr>
<tr>
<td colspan="18">SFP Module</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">PFT3950</td>
<td colspan="42">1.25G 850nm,500m,LC, Multi-mode</td>
</tr>
<tr>
<td colspan="18">PFT3960</td>
<td colspan="42">1.25G 1310/1550nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18">PFT3970</td>
<td colspan="42">1.25G 1550/1310nm,20km,LC, Single-mode</td>
</tr>
<tr>
<td colspan="18"></td>
<td colspan="42"></td>
</tr>
<tr>
<td colspan="18">EoC (Ethernet over Coax)</td>
<td colspan="42">Description</td>
</tr>
<tr>
<td colspan="18">LR1002</td>
<td colspan="42">1*10/100 Mbps Base-TX + 1*BNC</p>
<p>RG59 coaxial cable:</p>
<p>400m/100Mbps, 1000m/10Mbps</td>
</tr>
</tbody>
</table>
</div>
</div>
<div id="div_left">
<div class="div-drop">
<table id="table004" class="NEW-TABLE TableOverride-1 tab-drag">
<tbody>
<tr>
<td colspan="60">LED Indicator</td>
</tr>
<tr>
<td colspan="18">Working Mode</td>
<td colspan="42">LED Indicator</td>
</tr>
<tr>
<td colspan="18">IEEE mode</td>
<td colspan="42">Normally on</td>
</tr>
<tr>
<td colspan="18">E100</td>
<td colspan="42">On for 3 seconds, off for 1 second</td>
</tr>
<tr>
<td colspan="18">E10</td>
<td colspan="42">On for 1 second, off for 1 second</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
